The case of using the «chimney» technique in involuntary covering renal artery during abdominal aorta stenting

S.N. Furkalo

National Institute of Surgery and Transplantology after O.O. Shalimov of NAMS of Ukraine, Kyiv

      Example of successful use of endovascular techniques in case of complications of aortic replacement is presented. During installation phase of the endoprosthesis «Excluder-GORE» in patient with infrarenal abdominal aortic aneurysm involuntary covering the left renal artery with stent-graft occurred. The technique of «chimney» with renal artery stenting was used. Control angiography and later CT with contrast revealed a good result of endografting without endoliks and with good function of renal artery.

Key words: aortic aneurysm, aortic endografting, «chimney» technology.

 